Home / Products / OA-6000R

Phase Summary

Type: Ligand exchange-type
Active component: Inverted selector of OA-6000
Mode: Reversed phase ligand exchange
USP: Not specified

Customer Application

SUMICHIRAL OA-6000R is selected during chiral method development when the analyte profile matches amino acids, hydroxy acids, amino alcohols and hydrophilic amines. The phase is useful for direct enantiomeric separation, optical purity checking and impurity evaluation in research and QC workflows.

Related / Inversion Phase

Related inversion phase: OA-6000

Specifications

OA GelParticle SizeI.D.LengthUse
OA-6000R5 µm4.0 mm10 mmGuard / method protection
OA-6000R5 µm4.6 mm50 mmShort analytical
OA-6000R5 µm4.6 mm150 mmAnalytical
OA-6000R5 µm4.6 mm250 mmHigh resolution analytical

Why choose OA-6000R

This phase combines low-molecular-weight chiral recognition with reproducible silica-based column performance. Laboratories can use it to screen analytes by mode and selector chemistry, then request suitable dimensions for analytical or method confirmation work.

FAQs for this phase

These phase-specific answers help customers quickly understand selector chemistry, usage, USP reference and India supply support.

What is SUMICHIRAL OA-6000R used for?

SUMICHIRAL OA-6000R is used for direct chiral HPLC separation and optical purity evaluation. It is especially useful for amino acids, hydroxy acids, amino alcohols and hydrophilic amines.

What is the chiral selector or active component in OA-6000R?

The active component described for OA-6000R is Inverted selector of OA-6000. This selector chemistry helps laboratories screen suitable enantiomeric separation conditions.

Which HPLC mode is suitable for OA-6000R?

OA-6000R is listed for Reversed phase ligand exchange. Final mobile phase selection should be confirmed during method development based on analyte solubility, resolution and system suitability.

What USP classification is associated with OA-6000R?

OA-6000R is associated with USP Not specified. USP information helps customers compare phases during regulated method selection and documentation.

Can Akira Analytical Solutions support OA-6000R enquiries in India?

Yes. Akira Analytical Solutions Pvt. Ltd. can assist Indian customers with OA-6000R availability, quotation, dimensions and technical enquiry coordination for SUMICHIRAL columns.

Request OA-6000R

For availability, quotation and technical support, send the required dimensions and application details.

Contact supplier